A镇污水处理厂工艺设计毕业论文
2021-12-25 15:42:09
论文总字数:20169字
摘 要
本设计是针对苏北某市A镇生活污水处理的设计,目的主要是把城镇的生活污水集中至污水处理厂处理,使COD、BOD5、SS、氨氮、总磷、总氮出水达到要求的《城镇污水厂污染物排放标准》(GB18918-2002)一级A排放标准方可排放至自然水体中。该城市自然状况:年平均温度14.6℃,最高温度37.2℃,最低温度-8.6℃;年降雨量达1005.6mm;主导风向为夏季东南风,冬季西北风,无自发性震源,强度在4级以下。土壤冰冻深度0.24m。地下水水位:平均距地表3.2m。污水由管径1200mm的管道直接输送入污水处理厂格栅间,其管内底标高50.80m,充满度65%。污水排放水体最高水位48.50m,常水位47.20m,最低水位46.12m。厂区按整平地形考虑,平均标高为54.40m。
进入污水处理厂的水质情况:COD为230~380mg/L,BOD5为140~210mg/L,SS为230~260mg/L,NH3-N为28~35mg/L,TN为42~58mg/L,TP为2.2~4.6mg/L,PH为6~9。对城市污水处理厂目前国内基本都是用活性污泥工艺,由于该处理厂对脱氮除磷有要求,故活性污泥工艺可选用的有氧化沟工艺或者A/A/O工艺。本次设计中选用A/A/O工艺作为核心工艺。污水处理工艺流程如下所示:生活污水——格栅间——提升泵房——平流式初沉池——A/A/O反应池——斜管式二沉池——接触消毒池——出水;污泥处理工艺流程如下所示:斜管式二沉池——污泥浓缩池——带式压滤机——泥饼外运。
关键词:污水处理厂;活性污泥工艺;A/A/O工艺;污水处理工艺;污泥处理工艺。
Design of 50000 m3 / Durban Sewage Treatment Plant in a Town of a City in Northern Jiangsu Province
Abstract
This design is aimed at the design of domestic sewage treatment in a town of a city in Northern Jiangsu. The main purpose is to concentrate the domestic sewage in the town to the sewage treatment plant for treatment, so that the effluent of COD, BOD5, SS, ammonia nitrogen, total phosphorus and total nitrogen can be discharged into the natural water body only when it meets the class I a discharge standard of discharge standard for pollutants in urban sewage plant (GB18918-2002). The natural conditions of the city: the annual average temperature is 14.6 ℃, the maximum temperature is 37.2 ℃, the minimum temperature is - 8.6 ℃; the annual rainfall is 1005.6mm; the dominant wind direction is southeast wind in summer, northwest wind in winter, no spontaneous source, and the intensity is below grade 4. The freezing depth of soil is 0.24M. Groundwater level: 3.2m from the surface on average. The sewage is directly transported into the grid room of the sewage treatment plant by the pipe with the diameter of 1200mm. The elevation of the inner bottom of the pipe is 50.80m and the filling degree is 65%. The highest water level of sewage discharge water body is 48.50m, the normal water level is 47.20m, and the lowest water level is 46.12m. The plant area is considered as flat terrain, with an average elevation of 54.40m.
The water quality entering the sewage treatment plant: cod is 230-380mg / L, BOD5 is 140-210mg / L, SS is 230-260mg / L, NH3-N is 28-35mg / L, TN is 42-58mg / L, TP is 2.2-4.6mg/l, pH is 6-9. At present, the activated sludge process is basically used in urban sewage treatment plants in China. Because the treatment plant has requirements for nitrogen and phosphorus removal, oxidation ditch process or a / A / O process can be selected for the activated sludge process. A / A / O process is selected as the core process in this design. The process flow of sewage treatment is as follows: domestic sewage - grid room - lifting pump room - primary sedimentation tank - A / A / O reaction tank - radial flow sedimentation tank - contact disinfection tank - effluent; the process flow of sludge treatment is as follows: radial flow sedimentation tank - sludge concentration tank - belt filter Press - mud cake outward transportation.
Key Words:Sewage treatment plant; activated sludge process; A / A / O process; sewage treatment process; sludge treatment process.
目 录
摘 要 I
Abstract II
第一章 绪论 1
1.1国内污水处理现状及存在问题 1
1.2污水处理的工艺介绍及国外活性污泥法发展 1
1.3确定污水处理工艺的方法 2
第二章 设计任务书 4
2.1设计题目 4
2.2设计工程概述 4
2.3设计内容及要点 4
2.3.1设计内容 4
2.3.2设计要点 4
2.4设计任务 5
第三章 工艺的比选及确定 6
3.1工艺的比选 6
3.1.1核心工艺的选择 6
3.1.2泵房的选择 7
3.1.2沉淀池的选择 7
3.1.3消毒池的选择 8
3.2工艺的确定 8
3.3工艺流程 8
第四章 污水处理部分设计计算书 10
4.1格栅设计计算 10
4.1.1设计参数 10
4.1.2设计计算 10
4.2提升泵房设计计算 13
4.2.1确定流量 13
4.3.2估算扬程 13
4.3.3计算扬程 13
4.3.4集水池容积计算 14
4.3初沉池设计计算(斜板) 14
4.3.1设计参数 14
4.3.2设计计算 14
4.4A/A/O反应池设计计算 16
4.4.1设计参数 17
4.4.2设计计算 17
4.5二沉池设计计算(斜管式) 23
4.5.1设计参数 23
4.5.2设计计算 23
4.6消毒池设计计算(接触式) 25
4.6.1设计流量 25
4.6.2设计计算 25
第五章 污泥处理部分设计计算书 27
5.1污泥浓缩池设计计算(连续式中心传动) 27
5.1.1设计参数 27
5.1.2设计计算 27
5.2带式压滤机 28
5.2.1设计参数 28
5.2.2设计计算 29
第六章 水厂平面和高程布置 30
6.1水厂平面布置 30
6.2水厂高程布置 30
致 谢 33
参考文献 34
- 绪论
1.1国内污水处理现状及存在问题
现如今,随着我国工业的迅速发展,新建化工厂的数量也迅速增长,这就会导致难以处理的工业废水大量产生,有一些化工企业为了省钱经常会把工业污废水偷偷排放,这就导致水质土壤受到严重的影响,对生态环境和水资源破坏力巨大,地球虽然有很高的水覆盖率,但是淡水资源很少,真正能被人们利用的水资源并不多,仅仅只有地球上总水量的0.26%,而且分布的也及其不均匀,有的城市水源特别充足,有的却又十分稀缺,这就导致有些城市水比油贵的现象,而且随着全球人口的急剧增加,工业的迅速发展,水资源问题愈发被重视,生活污水、工业废水的乱排现象也管控的越来越严格;为了整治这种现象,我国对工业污废水排放的要求越来越严格,对一些工业废水严重超标的企业需要化工厂内自己建设污废水处理站对污废水处理达到一定的排放标准方可接入下一级处理厂进行处理达标排放。化工厂内所自建的污废水处理站主要是处理超标的有机化合物,因为污水处理厂对有机化合物的处理能力较差并且这些有机化学物质会对生化反应的微生物起抑制作用导致生化反应效率降低,处理达不到预期效果,故在接入污水处理厂前要让超标的有机化合物达到排放标准才行,处理有机化合物用到的是物化法,对污废水进行加药沉淀处理,使有机化合物得到高效的处理从而使其达到排放标准进入生化处理阶段。污废水的有效处理,不仅改善了我们用水的水质,也提高了生活环境的质量。