摘 要

某办公大楼,地上9层,地下1层,建筑高31.45m;地上1层和2层为商场,主楼为办公用房。建筑物南侧大道上有市政干管,市政管网可以提供的常年资用水头均为0.25Mpa,市政管网不允许直接抽水。西侧大道有市政污水管道。

给水系统分区供水,从市政管网上接一根DN100的引入管,负一层至地上二层为市政管网直供,三至九层采用无负压变频供水设备加压供水。消防水池置于地下室泵房外侧,有效容积432立方。建筑室内排水采用污、废水分流制,室外排水采用污废合流制,排入检查井后,经化粪池处理再排入市政污水管。卫生间采用多设立管形式,采用专用通气立管,部分增设环形通气管。地下室排水经排水沟汇集排至集水坑,经潜污泵提升排至检查井。雨水经屋面雨水斗收集后由雨水管排至检查井。

该建筑为二类高层建筑,室外消火栓用水量20L/s,室内消火栓用水量30L/s,火灾延续时间2h。消火栓充实水柱高度12m,水龙带长度25m,水枪喷嘴流量5.16L/s,消防立管管径为DN100。在屋顶层设试验消火栓一个,每个室内消火栓箱内均设有远距离启动消防泵的按钮。

该建筑采用湿式自动喷水灭火系统,喷淋系统设计流量40L/s。报警阀设于地下室泵房内,各层均设水流指示器、末端试水装置和信号阀,其信号均送入消防控制中心进行处理。本工程的自动喷水灭火系统分1个区。选用箱泵一体化消防增压稳压设备(包含18立方米消防水箱)贮存火灾初期10min自动喷水灭火系统、室内消火栓系统用水量,初期灭火由水箱供水,后期灭火由地下室的消防水泵和喷淋泵供水。

关键词:综合楼 给水系统 消防系统 排水系统 消火栓系统

A comprehensive office building water supply and drainage design

Abstract

A certain office building, the ground layer 9, 1 floor underground, the construction height o is 31.45 m; The ground layer 1 and layer 2 for market, the main building for office space. Amunicipal main avenue in the south building, municipal pipe network can be supported the perennial water head are 0.25 Mpa, municipal pipe network does not allow direct pumping. The west road of municipal sewage pipe.

Water supply system water supply division, from the municipal pipe network after the introduction of a DN100 tube, the negative a layer to the ground floor for the municipal pipe network for, three to nine layers by no negative pressure frequency conversion water supply equipment pressurized water supply. Fire pool in the basement pump room outside, the effective volume 432 cubic meters. Building indoor drainage using sewage, waste water diversion system, outdoor drainage using sewage waste confluence system, after checking well, into the septic tank treatment again into the municipal sewage pipe. Toilet USES special ventilation in the form of how to set up the tube, riser, part of the add circular vent. The drain converge to the basement drainage sump, the submersible sewage pump up to check well drained. The rain after roof rainwater hopper to collect from the storm sewer line to check well.

The building is for 2 kinds of high-rise buildings, outdoor fire hydrant water 20 l/s, indoor fire hydrant water 30 l/s, fire duration 2 h. Fire hydrant enrich water column 12 m in height, hose length is 25 m, spray nozzle flow 5.16 L/s, fire riser pipe diameter for the DN100. In fire hydrant a floor or roof experiment, each indoor fire hydrant boxes have remote button to start the fire pump.

The building adopts wet automatic sprinkler system, sprinkler system design flow, 40 l/s. Alarm valve is located in the basement pump room, each floor are set flow indicator, the end of the test device and the signal valve, the signals are sent to fire control center for processing. The project of automatic sprinkler system points 1 area. Selection box fire booster pump integration voltage equipment (including 18 cubic meters of water tank) storage fire early 10 min water automatic sprinkler system, indoor fire hydrant system, the early fire extinguishing by water tank water supply, the late fire from the basement of the fire pump and spray pump water supply.

Key words: Complex building water supply system fire protection system drainage system, fire hydrant system

目 录

第一章 任务书

一、设计任务书 1

1.1工程概况 1

1.2设计依据 1

1.3设计内容 2

1.4毕业设计(论文)图纸内容及张数 2

1.5设计进度计划 2

第二章 设计说明书

一、给水系统 3

1.1方案选择 3

1.2给水系统组成 3

二、消防系统 4

2.1室内消火栓系统 4

2.1.1室内消火栓系统的选择 4

2.1.2系统组成 5

2.1.3消火栓的安装 5

2.2自动喷淋系统 5

2.2.1室内自动喷水灭火系统的选择 5

2.2.2系统组成 6

2.2.3喷淋系统的安装 7

三、室内排水系统 7

3.1系统选择 7

3.2系统组成 8

四、雨水系统 9

4.1雨水排水系统的组成 9

第三章 设计计算书

一、给水系统计算 10

1.1生活用水量计算 10

1.2设计计算依据 10

1.3设计计算 11

1.4设计秒流量的确定 11

1.5水表的选择 11

1.6生活给水系统水力计算 12

1.6.1设计依据 12

1.6.2卫生间给水水力计算 14

1.6.3低区水力计算 16

1.6.4高区水力计算 17

1.7地下室生活水泵的选择 18

1.8低区给水系统所需压力校核 19

二、室内消火栓给水系统的计算 20

2.1消防水池 20

2.1.1消防水池的设置 20

2.1.2体积计算 20

2.2屋顶消防水箱 21

2.3消火栓保护半径 22

2.4消火栓布置间距 22

2.5消火栓的确定 23

2.6消火栓的水力计算 23

2.7水泵接合器选定 25

2.8消火栓减压计算 26

2.9室外消火栓的设置 26

三、自动喷水灭火系统 27

3.1自动喷淋灭火系统的基本数据 27

3.2管道与报警阀布置 27

3.3喷头的选用与布置 27

3.4系统的设计流量 27

3.5报警阀的压力损失 34

3.7选泵计算 34

3.8喷淋减压孔板计算 36

四、室内排水系统的设计与计算 37

4.1横支管的计算 37

4.2立管计算 41

4.3排出管计算 41

4.4集水坑及提升泵计算选型 42

4.4.1地下室车库集水坑计算 42

4.4.2水泵房集水坑及提升泵计算选型 43

4.5化粪池设计计算 44

五、建筑雨水排水系统的设计与计算 46

5.1降雨强度 46

5.2设计秒流量 47

5.3雨水斗选用 49

六、室外排水系统的设计与计算 51

6.1室外雨水管网计算 51

6.2室外污水管网计算 52