登录

  • 登录
  • 忘记密码?点击找回

注册

  • 获取手机验证码 60
  • 注册

找回密码

  • 获取手机验证码60
  • 找回
毕业论文网 > 文献综述 > 土木建筑类 > 给排水科学与工程 > 正文

某制药废水处理工程设计文献综述

 2020-06-12 20:16:37  

微电解#8212;Fenton试剂氧化#8212;A/O工艺处理制药废水

摘要: 采用微电解#8212;Fenton试剂氧化#8212;A/O组合工艺处理高浓度制药废水。实验结果表明:经微电解#8212;Fenton试剂氧化工艺预处理后,COD去除率可达50%~60%,BOD5/COD提高到0.3以上;预处理后的废水与清洗废水和生活污水混合,采用生化法进一步处理,出水COD小于100 mg/L,BOD5小于20 mg/L,ρ(NH3-N)小于50 mg/ L,SS小于70 mg/L,满足GB 8978#8212;1996《污水综合排放标准》中的三级排放标准。

关键词: 制药废水;微电解;Fenton试剂氧化;生化处理

Treatment of pharmaceutical wastewater by micro electrolysis Fenton reagent oxidation A/O process

Abstract: The high-concentration pharmaceutical wastewater was treated by a combination process of micro-electrolysis-Fenton reagent oxidation -A/O biotreatment. The experimental results show that:After pretreatment of micro-electrolysis-Fenton reagent oxidation,the COD remove rate is 50%-60%,and BOD5/COD is increased to above 0.3;Mixed with washing wastewater and domestic sewage,the pretreated wastewater is then treated by biological method,the COD,BOD5,ρ(NH3-N),SS of the effluent are less than 100,20,50,70 mg/L respectively,which meet the third grade discharge standard of GB 8978#8212;1996.

Key words: pharmaceutical wastewater;micro-electrolysis;Fenton reagent oxidation;biotreatment

剩余内容已隐藏,您需要先支付 5元 才能查看该篇文章全部内容!立即支付

微信号:bysjorg

Copyright © 2010-2022 毕业论文网 站点地图